PCI=Peripheral Component Interconnect
IndustrialPCI is a version of PCI adapted for industrial and/or embedded applications.
The IPCI connector has three parts:
- Optional 60 pin PCI 64 bit extension (Top)
- Mandatory 120 pin PCI 32 bit (Middle)
- Optional 60 pin Custom I/O (Bottom)
Pinout
UNKNOWN CONNECTOR at the backplane.
UNKNOWN CONNECTOR at the device (card).
System Slot (Middle)
Pin |
Name |
Description |
Note
|
A1 |
+3,3V |
+3.3 VDC |
|
A2 |
AD2 |
Address 2 |
|
A3 |
AD6 |
Address 6 |
|
A4 |
GND |
Ground |
|
A5 |
AD10 |
Address 10 |
|
A6 |
AD13 |
Address 13 |
|
A7 |
GND |
Ground |
|
A8 |
SDONE |
Snoop Done |
1
|
A9 |
GND |
Ground |
|
A10 |
FRAME# |
Indicate Address or Data phase |
1
|
A11 |
AD18 |
Address 18 |
|
A12 |
GND |
Ground |
|
A13 |
+5V |
+5 VDC |
|
A14 |
AD24 |
Address 24 |
|
A15 |
AD27 |
Address 27 |
|
A16 |
GND |
Ground |
|
A17 |
REQ2 |
Request 2 |
1
|
A18 |
GND |
Ground |
|
A19 |
CLK1 |
33 or 66 MHz Clock |
|
A20 |
CLK2 |
|
|
A21 |
GND |
Ground |
|
A22 |
CLK3 |
|
|
A23 |
CLK4 |
|
|
A24 |
+3,3V |
+3.3 VDC |
|
B1 |
REQ64# |
Request 64 ??? |
1
|
B2 |
AD3 |
Address 3 |
|
B3 |
+5V |
+5 VDC |
|
B4 |
AD8 |
Address 8 |
|
B5 |
+3,3V |
+3.3 VDC |
|
B6 |
AD14 |
Address 14 |
|
B7 |
PAR |
Parity |
|
B8 |
+3,3V |
+3.3 VDC |
|
B9 |
STOP# |
Stop |
1
|
B10 |
C/BE2# |
Command, Byte Enable 2 |
|
B11 |
V(I/O) |
+3.3 or +5 VDC |
|
B12 |
AD21 |
Address 21 |
|
B13 |
+3,3V |
+3.3 VDC |
|
B14 |
V(I/O) |
+3.3 or +5 VDC |
|
B15 |
AD28 |
Address 28 |
|
B16 |
AD31 |
Address 31 |
|
B17 |
+3,3V |
+3.3 VDC |
|
B18 |
GNT3 |
Grant 3 |
|
B19 |
RST# |
Reset |
|
B20 |
NMI# |
Non Maskable Interrupt |
|
B21 |
X6 |
Reserved (6) |
|
B22 |
+5V |
+5 VDC |
:
|
B23 |
RSTIN# |
|
2
|
B24 |
USB+ |
Universal Serial Bus (USB)(+) |
|
C1 |
ACK64# |
Acknowledge 64 ??? |
1
|
C2 |
GND |
Ground |
|
C3 |
AD7 |
Address 7 |
|
C4 |
AD9 |
Address 9 |
|
C5 |
AD11 |
Address 11 |
|
C6 |
GND |
Ground |
|
C7 |
SERR# |
System Error |
1
|
C8 |
PERR# |
Parity Error |
1
|
C9 |
DEVSEL# |
Device Select |
1
|
C10 |
GND |
Ground |
|
C11 |
AD19 |
Address 19 |
|
C12 |
AD22 |
Address 22 |
|
C13 |
GND |
Ground |
|
C14 |
AD25 |
Address 25 |
|
C15 |
GND |
Ground |
|
C16 |
X1 |
Reserved (1) |
|
C17 |
GNT2 |
Grant 2 |
|
C18 |
REQ4 |
Request 4 |
1
|
C19 |
SLEEP#/SDAT |
Sleep/Serial Data (I2C) |
3
|
C20 |
X4 |
Reserved (4) |
|
C21 |
INTD# |
Interrupt D |
1
|
C22 |
INTB# |
Interrupt B |
1
|
C23 |
+5V |
+5 VDC |
|
C24 |
USB- |
Universal Serial Bus (USB)(-) |
|
D1 |
AD0 |
Address 0 |
|
D2 |
AD4 |
Address 4 |
|
D3 |
C/BE0# |
Command, Byte Enable 0 |
|
D4 |
+3,3V |
+3.3 VDC |
|
D5 |
AD12 |
Address 12 |
|
D6 |
AD15 |
Address 15 |
|
D7 |
V(I/O) |
+3.3 or +5 VDC |
|
D8 |
LOCK# |
Resource Lock |
1
|
D9 |
TRDY# |
Test Logic Ready |
1
|
D10 |
AD16 |
Address 16 |
|
D11 |
AD20 |
Address 20 |
|
D12 |
+5V |
+5 VDC |
|
D13 |
+5V |
+5 VDC |
|
D14 |
AD26 |
Address 26 |
|
D15 |
AD29 |
Address 29 |
|
D16 |
REQ1 |
Request 1 |
1
|
D17 |
REQ3 |
Request 3 |
1
|
D18 |
V(I/O) |
+3.3 or +5 VDC |
|
D19 |
X2 |
Reserved (2) |
|
D20 |
X5 |
Reserved (5) |
|
D21 |
+3,3V |
+3.3 VDC |
|
D22 |
INTA# |
Interrupt A |
1
|
D23 |
ICPEN#/SCLK |
ICPEN/Serial Clock (I2C) |
3
|
D24 |
OSC (PWDN) |
|
|
E1 |
AD1 |
Address 1 |
|
E2 |
AD5 |
Address 5 |
|
E3 |
GND |
Ground |
|
E4 |
M66EN |
Enable 66Mhz PCI-bus |
|
E5 |
GND |
Ground |
|
E6 |
C/BE1# |
Command, Byte Enable 1 |
|
E7 |
SBO# |
Snoop Backoff |
1
|
E8 |
+5V |
+5 VDC |
|
E9 |
IRDY# |
Initiator Ready |
1
|
E10 |
AD17 |
Address 17 |
|
E11 |
GND |
Ground |
|
E12 |
AD23 |
Address 23 |
|
E13 |
C/BE3# |
Command, Byte Enable 3 |
|
E14 |
GND |
Ground |
|
E15 |
AD30 |
Address 30 |
|
E16 |
GNT1 |
Grant 1 |
|
E17 |
+5V |
+5 VDC |
|
E18 |
GNT4 |
Grant 4 |
|
E19 |
X3 |
Reserved (3) |
|
E20 |
GND |
Ground |
|
E21 |
INTC# |
Interrupt C |
1
|
E22 |
-12V |
-12 VDC |
|
E23 |
+12V |
+12 VDC |
|
E24 |
VBATT |
|
|
1 = Pullup resistor of 2,7 kOhm on the System Slot (CPU).
2 = Pullup resistor of 330 ohm on the System Slot (CPU).
3 = Pullup resistor of 4,7 KB ohm, if not supported by the System Slot (CPU).
Module Bus Slot (Middle)
Pin |
Name |
Description |
Note
|
A1 |
+3,3V |
+3.3 VDC |
|
A2 |
AD2 |
Address 2 |
|
A3 |
AD6 |
Address 6 |
|
A4 |
GND |
Ground |
|
A5 |
AD10 |
Address 10 |
|
A6 |
AD13 |
Address 13 |
|
A7 |
GND |
Ground |
|
A8 |
SDONE |
Snoop Done |
1
|
A9 |
GND |
Ground |
|
A10 |
FRAME# |
Indicate Address or Data phase |
1
|
A11 |
AD18 |
Address 18 |
|
A12 |
GND |
Ground |
|
A13 |
+5V |
+5 VDC |
|
A14 |
AD24 |
Address 24 |
|
A15 |
AD27 |
Address 27 |
|
A16 |
GND |
Ground |
|
A17 |
REQ2 |
Request 2 |
1
|
A18 |
CLKM |
|
|
A19 |
CLK1 |
33 or 66 MHz Clock |
|
A20 |
CLK2 |
|
|
A21 |
GND |
Ground |
|
A22 |
CLK3 |
|
|
A23 |
CLK4 |
|
|
A24 |
+3,3V |
+3.3 VDC |
|
B1 |
REQ64# |
Request 64 ??? |
1
|
B2 |
AD3 |
Address 3 |
|
B3 |
+5V |
+5 VDC |
|
B4 |
AD8 |
Address 8 |
|
B5 |
+3,3V |
+3.3 VDC |
|
B6 |
AD14 |
Address 14 |
|
B7 |
PAR |
Parity |
|
B8 |
+3,3V |
+3.3 VDC |
|
B9 |
STOP# |
Stop |
1
|
B10 |
C/BE2# |
Command, Byte Enable 2 |
|
B11 |
V(I/O) |
+3.3 or +5 VDC |
|
B12 |
AD21 |
Address 21 |
|
B13 |
+3,3V |
+3.3 VDC |
|
B14 |
V(I/O) |
+3.3 or +5 VDC |
|
B15 |
AD28 |
Address 28 |
|
B16 |
AD31 |
Address 31 |
|
B17 |
+3,3V |
+3.3 VDC |
|
B18 |
GNT3 |
Grant 3 |
|
B19 |
RST# |
Reset |
|
B20 |
NMI# |
Non Maskable Interrupt |
|
B21 |
X6 |
Reserved (6) |
|
B22 |
+5V |
+5 VDC |
:
|
B23 |
RSTIN# |
|
|
B24 |
USB+ |
Universal Serial Bus (USB)(+) |
|
C1 |
ACK64# |
Acknowledge 64 ??? |
1
|
C2 |
GND |
Ground |
|
C3 |
AD7 |
Address 7 |
|
C4 |
AD9 |
Address 9 |
|
C5 |
AD11 |
Address 11 |
|
C6 |
GND |
Ground |
|
C7 |
SERR# |
System Error |
1
|
C8 |
PERR# |
Parity Error |
1
|
C9 |
DEVSEL# |
Device Select |
1
|
C10 |
GND |
Ground |
|
C11 |
AD19 |
Address 19 |
|
C12 |
AD22 |
Address 22 |
|
C13 |
GND |
Ground |
|
C14 |
AD25 |
Address 25 |
|
C15 |
GND |
Ground |
|
C16 |
X1 |
Reserved (1) |
|
C17 |
GNT2 |
Grant 2 |
|
C18 |
REQ4 |
Request 4 |
1
|
C19 |
SLEEP#/SDAT |
Sleep/Serial Data (I2C) |
|
C20 |
X4 |
Reserved (4) |
|
C21 |
INTD# |
Interrupt D |
1
|
C22 |
INTB# |
Interrupt B |
1
|
C23 |
+5V |
+5 VDC |
|
C24 |
USB- |
Universal Serial Bus (USB)(-) |
|
D1 |
AD0 |
Address 0 |
|
D2 |
AD4 |
Address 4 |
|
D3 |
C/BE0# |
Command, Byte Enable 0 |
|
D4 |
+3,3V |
+3.3 VDC |
|
D5 |
AD12 |
Address 12 |
|
D6 |
AD15 |
Address 15 |
|
D7 |
V(I/O) |
+3.3 or +5 VDC |
|
D8 |
LOCK# |
Resource Lock |
1
|
D9 |
TRDY# |
Test Logic Ready |
1
|
D10 |
AD16 |
Address 16 |
|
D11 |
AD20 |
Address 20 |
|
D12 |
+5V |
+5 VDC |
|
D13 |
+5V |
+5 VDC |
|
D14 |
AD26 |
Address 26 |
|
D15 |
AD29 |
Address 29 |
|
D16 |
REQ1 |
Request 1 |
1
|
D17 |
REQ3 |
Request 3 |
1
|
D18 |
V(I/O) |
+3.3 or +5 VDC |
|
D19 |
X2 |
Reserved (2) |
|
D20 |
X5 |
Reserved (5) |
|
D21 |
+3,3V |
+3.3 VDC |
|
D22 |
INTA# |
Interrupt A |
1
|
D23 |
ICPEN#/SCLK |
ICPEN/Serial Clock (I2C) |
3
|
D24 |
OSC (PWDN) |
|
|
E1 |
AD1 |
Address 1 |
|
E2 |
AD5 |
Address 5 |
|
E3 |
GND |
Ground |
|
E4 |
M66EN |
Enable 66Mhz PCI-bus |
|
E5 |
GND |
Ground |
|
E6 |
C/BE1# |
Command, Byte Enable 1 |
|
E7 |
SBO# |
Snoop Backoff |
1
|
E8 |
+5V |
+5 VDC |
|
E9 |
IRDY# |
Initiator Ready |
1
|
E10 |
AD17 |
Address 17 |
|
E11 |
GND |
Ground |
|
E12 |
AD23 |
Address 23 |
|
E13 |
C/BE3# |
Command, Byte Enable 3 |
|
E14 |
GND |
Ground |
|
E15 |
AD30 |
Address 30 |
|
E16 |
GNT1 |
Grant 1 |
|
E17 |
+5V |
+5 VDC |
|
E18 |
GNT4 |
Grant 4 |
|
E19 |
X3 |
Reserved (3) |
|
E20 |
GND |
Ground |
|
E21 |
INTC# |
Interrupt C |
1
|
E22 |
-12V |
-12 VDC |
|
E23 |
+12V |
+12 VDC |
|
E24 |
VBATT |
|
|
1 = Pullup resistor of 2,7 kOhm on the System Slot (CPU).
Card Slot (Middle)
Pin |
Name |
Description |
Note
|
A1 |
+3,3V |
+3.3 VDC |
|
A2 |
AD2 |
Address 2 |
|
A3 |
AD6 |
Address 6 |
|
A4 |
GND |
Ground |
|
A5 |
AD10 |
Address 10 |
|
A6 |
AD13 |
Address 13 |
|
A7 |
GND |
Ground |
|
A8 |
SDONE |
Snoop Done |
1
|
A9 |
GND |
Ground |
|
A10 |
FRAME# |
Indicate Address or Data phase |
1
|
A11 |
AD18 |
Address 18 |
|
A12 |
GND |
Ground |
|
A13 |
+5V |
+5 VDC |
|
A14 |
AD24 |
Address 24 |
|
A15 |
AD27 |
Address 27 |
|
A16 |
GND |
Ground |
|
A17 |
IDSEL0 |
IDSEL0 |
1
|
A18 |
GND |
Ground |
|
A19 |
CLK1 |
33 or 66 MHz Clock |
|
A20 |
GND |
Ground |
|
A21 |
GND |
Ground |
|
A22 |
GND |
Ground |
|
A23 |
GND |
Ground |
|
A24 |
+3,3V |
+3.3 VDC |
|
B1 |
REQ64# |
Request 64 ??? |
1
|
B2 |
AD3 |
Address 3 |
|
B3 |
+5V |
+5 VDC |
|
B4 |
AD8 |
Address 8 |
|
B5 |
+3,3V |
+3.3 VDC |
|
B6 |
AD14 |
Address 14 |
|
B7 |
PAR |
Parity |
|
B8 |
+3,3V |
+3.3 VDC |
|
B9 |
STOP# |
Stop |
1
|
B10 |
C/BE2# |
Command, Byte Enable 2 |
|
B11 |
V(I/O) |
+3.3 or +5 VDC |
|
B12 |
AD21 |
Address 21 |
|
B13 |
+3,3V |
+3.3 VDC |
|
B14 |
V(I/O) |
+3.3 or +5 VDC |
|
B15 |
AD28 |
Address 28 |
|
B16 |
AD31 |
Address 31 |
|
B17 |
+3,3V |
+3.3 VDC |
|
B18 |
GND |
Ground |
|
B19 |
RST# |
Reset |
|
B20 |
NMI# |
Non Maskable Interrupt |
|
B21 |
X6 |
Reserved (6) |
|
B22 |
+5V |
+5 VDC |
:
|
B23 |
RSTIN# |
|
|
B24 |
USB+ |
Universal Serial Bus (USB)(+) |
|
C1 |
ACK64# |
Acknowledge 64 ??? |
1
|
C2 |
GND |
Ground |
|
C3 |
AD7 |
Address 7 |
|
C4 |
AD9 |
Address 9 |
|
C5 |
AD11 |
Address 11 |
|
C6 |
GND |
Ground |
|
C7 |
SERR# |
System Error |
1
|
C8 |
PERR# |
Parity Error |
1
|
C9 |
DEVSEL# |
Device Select |
1
|
C10 |
GND |
Ground |
|
C11 |
AD19 |
Address 19 |
|
C12 |
AD22 |
Address 22 |
|
C13 |
GND |
Ground |
|
C14 |
AD25 |
Address 25 |
|
C15 |
GND |
Ground |
|
C16 |
X1 |
Reserved (1) |
|
C17 |
IDSEL1 |
Initialization Device Select 1 |
|
C18 |
GND |
Ground |
|
C19 |
SLEEP#/SDAT |
Sleep/Serial Data (I2C) |
|
C20 |
X4 |
Reserved (4) |
|
C21 |
INTD# |
Interrupt D |
1
|
C22 |
INTB# |
Interrupt B |
1
|
C23 |
+5V |
+5 VDC |
|
C24 |
USB- |
Universal Serial Bus (USB)(-) |
|
D1 |
AD0 |
Address 0 |
|
D2 |
AD4 |
Address 4 |
|
D3 |
C/BE0# |
Command, Byte Enable 0 |
|
D4 |
+3,3V |
+3.3 VDC |
|
D5 |
AD12 |
Address 12 |
|
D6 |
AD15 |
Address 15 |
|
D7 |
V(I/O) |
+3.3 or +5 VDC |
|
D8 |
LOCK# |
Resource Lock |
1
|
D9 |
TRDY# |
Test Logic Ready |
1
|
D10 |
AD16 |
Address 16 |
|
D11 |
AD20 |
Address 20 |
|
D12 |
+5V |
+5 VDC |
|
D13 |
+5V |
+5 VDC |
|
D14 |
AD26 |
Address 26 |
|
D15 |
AD29 |
Address 29 |
|
D16 |
REQ1 |
Request 1 |
1
|
D17 |
IDSEL2 |
Initialization Device Select 2 |
|
D18 |
V(I/O) |
+3.3 or +5 VDC |
|
D19 |
X2 |
Reserved (2) |
|
D20 |
X5 |
Reserved (5) |
|
D21 |
+3,3V |
+3.3 VDC |
|
D22 |
INTA# |
Interrupt A |
1
|
D23 |
ICPEN#/SCLK |
ICPEN/Serial Clock (I2C) |
3
|
D24 |
OSC (PWDN) |
|
|
E1 |
AD1 |
Address 1 |
|
E2 |
AD5 |
Address 5 |
|
E3 |
GND |
Ground |
|
E4 |
M66EN |
Enable 66Mhz PCI-bus |
|
E5 |
GND |
Ground |
|
E6 |
C/BE1# |
Command, Byte Enable 1 |
|
E7 |
SBO# |
Snoop Backoff |
1
|
E8 |
+5V |
+5 VDC |
|
E9 |
IRDY# |
Initiator Ready |
1
|
E10 |
AD17 |
Address 17 |
|
E11 |
GND |
Ground |
|
E12 |
AD23 |
Address 23 |
|
E13 |
C/BE3# |
Command, Byte Enable 3 |
|
E14 |
GND |
Ground |
|
E15 |
AD30 |
Address 30 |
|
E16 |
GNT1 |
Grant 1 |
|
E17 |
+5V |
+5 VDC |
|
E18 |
GNT4 |
Grant 4 |
|
E19 |
X3 |
Reserved (3) |
|
E20 |
GND |
Ground |
|
E21 |
INTC# |
Interrupt C |
1
|
E22 |
-12V |
-12 VDC |
|
E23 |
+12V |
+12 VDC |
|
E24 |
VBATT |
|
|
1 = Pullup resistor of 2,7 kOhm on the System Slot (CPU).
64-bit PCI (Top)
Pin |
Name |
Description |
Note
|
A1 |
GND |
Ground |
|
A2 |
X10 |
Reserved (10) |
|
A3 |
AD35 |
Address 35 |
2
|
A4 |
AD38 |
Address 38 |
2
|
A5 |
AD42 |
Address 42 |
2
|
A6 |
V(I/O) |
+3.3 or +5 VDC |
|
A7 |
V(I/O) |
+3.3 or +5 VDC |
|
A8 |
AD52 |
Address 52 |
2
|
A9 |
AD56 |
Address 56 |
2
|
A10 |
AD60 |
Address 60 |
2
|
A11 |
AD63 |
Address 63 |
2
|
A12 |
GND |
Ground |
|
B1 |
X7 |
Reserved (7) |
|
B2 |
GND |
Ground |
|
B3 |
AD36 |
Address 36 |
2
|
B4 |
AD39 |
Address 39 |
2
|
B5 |
AD43 |
Address 43 |
2
|
B6 |
AD46 |
Address 46 |
2
|
B7 |
AD49 |
Address 49 |
2
|
B8 |
AD53 |
Address 53 |
2
|
B9 |
AD57 |
Address 57 |
2
|
B10 |
AD61 |
Address 61 |
2
|
B11 |
GND |
Ground |
|
B12 |
C/BE6# |
Command, Byte Enable 6 |
2
|
C1 |
X8 |
Reserved (8) |
|
C2 |
AD32 |
Address 32 |
2
|
C3 |
GND |
Ground |
|
C4 |
AD40 |
Address 40 |
2
|
C5 |
AD44 |
Address 44 |
2
|
C6 |
GND |
Ground |
|
C7 |
GND |
Ground |
|
C8 |
AD54 |
Address 54 |
2
|
C9 |
AD58 |
Address 58 |
2
|
C10 |
GND |
Ground |
|
C11 |
PAR64 |
Parity 64 ??? |
2
|
C12 |
C/BE7# |
Command, Byte Enable 7 |
2
|
D1 |
X9 |
Reserved (9) |
|
D2 |
AD33 |
Address 33 |
2
|
D3 |
AD37 |
Address 37 |
2
|
D4 |
GND |
Ground |
|
D5 |
AD45 |
Address 45 |
2
|
D6 |
AD47 |
Address 47 |
2
|
D7 |
AD50 |
Address 50 |
2
|
D8 |
AD55 |
Address 55 |
2
|
D9 |
GND |
Ground |
|
D10 |
AD62 |
Address 62 |
2
|
D11 |
C/BE4# |
Command, Byte Enable 4 |
2
|
D12 |
X11 |
Reserved (11) |
|
E1 |
GND |
Ground |
|
E2 |
AD34 |
Address 34 |
2
|
E3 |
V(I/O) |
+3.3 or +5 VDC |
|
E4 |
AD41 |
Address 41 |
2
|
E5 |
GND |
Ground |
|
E6 |
AD48 |
Address 48 |
2
|
E7 |
AD51 |
Address 51 |
2
|
E8 |
GND |
Ground |
|
E9 |
AD59 |
Address 59 |
2
|
E10 |
V(I/O) |
+3.3 or +5 VDC |
|
E11 |
C/BE5# |
Command, Byte Enable 5 |
2
|
E12 |
X12 |
Reserved (12) |
|
2 = Pullup resistor of 2,7 kOhm (5V bus system) or 8,2 kOhm
(3,3V bus system) on the backplane.
ISA96/AT96 (Bottom)
Pin |
Name |
Description |
Note
|
A1 |
RSTDRV |
|
|
A2 |
IRQ9 |
Interrupt 9 |
|
A3 |
SD11 |
Data 11 |
|
A4 |
SD9 |
Data 9 |
|
A5 |
IOCHRDY |
|
1
|
A6 |
IOW# |
I/O Write |
|
A7 |
SA15 |
Address 15 |
|
A8 |
CLK |
Clock |
|
A9 |
SA10 |
Address 10 |
|
A10 |
SA7 |
Address 7 |
|
A11 |
T/C |
|
|
A12 |
SA2 |
Address 2 |
|
B1 |
SD15 |
Data 15 |
|
B2 |
SD13 |
Data 13 |
|
B3 |
SD3 |
Data 3 |
|
B4 |
SD1 |
Data 1 |
|
B5 |
SMEMW# |
System Memory Write |
|
B6 |
SA18 |
Address 18 |
|
B7 |
SA14 |
Address 14 |
|
B8 |
DACK6# |
DMA Acknowledge 6 |
|
B9 |
SA9 |
Address 9 |
|
B10 |
IRQ3 |
Interrupt 3 |
|
B11 |
IOCS16# |
I/O 16-bit chip select |
1
|
B12 |
SA1 |
Address 1 |
|
C1 |
SD7 |
Data 7 |
|
C2 |
SD5 |
Data 5 |
|
C3 |
SD10 |
Data 10 |
|
C4 |
SD8 |
Data 8 |
|
C5 |
AEN |
Address Enable |
|
C6 |
IOR# |
I/O Read |
|
C7 |
SA13 |
Address 13 |
|
C8 |
SA11 |
Address 11 |
|
C9 |
IRQ5 |
Interrupt 5 |
|
C10 |
SA6 |
Address 6 |
|
C11 |
SA4 |
Address 4 |
|
C12 |
IRQ11 |
Interrupt 11 |
|
D1 |
SD14 |
Data 14 |
|
D2 |
SD12 |
Data 12 |
|
D3 |
SD2 |
Data 2 |
|
D4 |
SD0 |
Data 0 |
|
D5 |
SMEMR# |
System Memory Read |
|
D6 |
SA17 |
Address 17 |
|
D7 |
REF# |
|
|
D8 |
IRQ7 |
Interrupt 7 |
|
D9 |
SA8 |
Address 8 |
|
D10 |
MCS16# |
|
1
|
D11 |
BALE |
|
|
D12 |
SA0 |
Address 0 |
|
E1 |
SD6 |
Data 6 |
|
E2 |
SD4 |
Data 4 |
|
E3 |
0WS |
|
1
|
E4 |
SBHE# |
|
|
E5 |
SA19 |
Address 19 |
|
E6 |
SA16 |
Address 16 |
|
E7 |
SA12 |
Address 12 |
|
E8 |
DRQ6 |
DMA Request 6 |
|
E9 |
IRQ4 |
Interrupt 4 |
|
E10 |
SA5 |
Address 5 |
|
E11 |
SA3 |
Address 3 |
|
E12 |
IRQ10 |
Interrupt 10 |
|
1 = Pullup resistor must be integrated into the System Slot
(CPU).
VMEbus (Bottom)
Pin |
Name |
Description
|
A1 |
D0 |
Data 0
|
A2 |
D2 |
Data 2
|
A3 |
D12 |
Data 12
|
A4 |
D7 |
Data 7
|
A5 |
DS1# |
|
A6 |
BR3# |
|
A7 |
AM1 |
|
A8 |
AM3 |
|
A9 |
IACKOUT# |
|
A10 |
A14 |
Address 14
|
A11 |
A12 |
Address 12
|
A12 |
A10 |
Address 10
|
B1 |
BBSY# |
|
B2 |
D10 |
Data 10
|
B3 |
D5 |
Data 5
|
B4 |
D15 |
Data 15
|
B5 |
SYSRES# |
|
B6 |
A23 |
Address 23
|
B7 |
A21 |
Address 21
|
B8 |
A19 |
Address 19
|
B9 |
A16 |
Address 16
|
B10 |
A6 |
Address 6
|
B11 |
A4 |
Address 4
|
B12 |
A2 |
Address 2
|
C1 |
D8 |
Data 8
|
C2 |
D3 |
Data 3
|
C3 |
D13 |
Data 13
|
C4 |
SYSCLK |
|
C5 |
DS0# |
|
C6 |
DTACK# |
|
C7 |
AS# |
|
C8 |
IACK# |
|
C9 |
AM4 |
|
C10 |
A13 |
Address 13
|
C11 |
A11 |
Address 11
|
C12 |
A9 |
Address 9
|
D1 |
D1 |
Data 1
|
D2 |
D11 |
Data 11
|
D3 |
D6 |
Data 6
|
D4 |
BG3OUT# |
|
D5 |
WR# |
Write
|
D6 |
AM0 |
|
D7 |
AM2 |
|
D8 |
A18 |
Address 18
|
D9 |
A15 |
Address 15
|
D10 |
A5 |
Address 5
|
D11 |
A3 |
Address 3
|
D12 |
A1 |
Address 1
|
E1 |
D9 |
Data 9
|
E2 |
D4 |
Data 4
|
E3 |
D14 |
Data 14
|
E4 |
BERR# |
Bus Error
|
E5 |
AM5 |
|
E6 |
A22 |
Address 22
|
E7 |
A20 |
Address 20
|
E8 |
A17 |
Address 17
|
E9 |
A7 |
Address 7
|
E10 |
IRQ5# |
Interrupt 5
|
E11 |
IRQ3# |
Interrupt 3
|
E12 |
A8 |
Address 8
|
ECB (Bottom)
Pin |
Name |
Description
|
A1 |
D5 |
Data 5
|
A2 |
D2 |
Data 2
|
A3 |
A4 |
Data 4
|
A4 |
A7 |
Address 7
|
A5 |
BAI |
|
A6 |
2F |
|
A7 |
A10 |
Address 10
|
A8 |
INT# |
|
A9 |
VCMOS |
|
A10 |
PWRCLR# |
|
A11 |
A13 |
Address 13
|
A12 |
RESET# |
Reset
|
B1 |
D0 |
Data 0
|
B2 |
D4 |
Data 4
|
B3 |
A1 |
Address 1
|
B4 |
WAIT# |
|
B5 |
A17 |
Address 17
|
B6 |
IEO |
|
B7 |
n/c |
Not connected
|
B8 |
DMARDY |
|
B9 |
RD# |
Read
|
B10 |
IORQ# |
|
B11 |
? |
|
B12 |
n/c |
Not connected
|
C1 |
D6 |
Data 6
|
C2 |
A0 |
Address 0
|
C3 |
A5 |
Address 5
|
C4 |
A16 |
Address 16
|
C5 |
A18 |
Address 18
|
C6 |
BAO |
|
C7 |
M1# |
|
C8 |
WR# |
|
C9 |
n |
|
C10 |
A12 |
Address 12
|
C11 |
A9 |
Address 9
|
C12 |
n/c |
Not connected
|
D1 |
D7 |
Data 7
|
D2 |
A2 |
Address 2
|
D3 |
A8 |
Address 8
|
D4 |
BUSRQ# |
|
D5 |
A19 |
Address 19
|
D6 |
A11 |
Address 11
|
D7 |
NMI# |
Non Maskable Interrupt
|
D8 |
PF |
|
D9 |
HALT# |
|
D10 |
RFSH# |
|
D11 |
MRQ# |
|
D12 |
n/c |
Not connected
|
E1 |
D3 |
Data 3
|
E2 |
A3 |
Address 3
|
E3 |
A6 |
Address 6
|
E4 |
IEI |
|
E5 |
D1 |
Data 1
|
E6 |
A14 |
Address 14
|
E7 |
n/c |
Not connected
|
E8 |
n/c |
Not connected
|
E9 |
DESLCT# |
|
E10 |
A15 |
Address 15
|
E11 |
BUSAK# |
|
E12 |
n/c |
Not connected
|
SMP16 (Bottom)
Pin |
Name |
Description
|
A1 |
NMI# |
Non Maskable Interrupt
|
A2 |
IRQ0# |
Interrupt 0
|
A3 |
D11 |
Data 11
|
A4 |
D9 |
Data 9
|
A5 |
RDYIN |
|
A6 |
IOW# |
|
A7 |
A15 |
Address 15
|
A8 |
CLK |
|
A9 |
A10 |
Address 10
|
A10 |
A7 |
Address 7
|
A11 |
TC/EOP# |
|
A12 |
A2 |
Address 2
|
B1 |
D15 |
Data 15
|
B2 |
D13 |
Data 13
|
B3 |
D3 |
Data 3
|
B4 |
D1 |
Data 1
|
B5 |
MEMW# |
|
B6 |
A18 |
Address 18
|
B7 |
A14 |
Address 14
|
B8 |
DACKx# |
|
B9 |
A9 |
Address 9
|
B10 |
IRQ3# |
Interrupt 3
|
B11 |
IOCS16# |
|
B12 |
A1 |
Address 1
|
C1 |
D7 |
Data 7
|
C2 |
D5 |
Data 5
|
C3 |
D10 |
Data 10
|
C4 |
D8 |
Data 8
|
C5 |
BUSEN |
|
C6 |
IOR# |
|
C7 |
A13 |
Address 13
|
C8 |
A11 |
Address 11
|
C9 |
IRQ1# |
Interrupt 1
|
C10 |
A6 |
Address 6
|
C11 |
A4 |
Address 4
|
C12 |
IRQ4# |
Interrupt 4
|
D1 |
D14 |
Data 14
|
D2 |
D12 |
Data 12
|
D3 |
D2 |
Data 2
|
D4 |
D0 |
Data 0
|
D5 |
MEMR# |
|
D6 |
A17 |
Address 17
|
D7 |
INTA# |
|
D8 |
INT# |
|
D9 |
A8 |
Address 8
|
D10 |
MECS16# |
|
D11 |
ALE |
|
D12 |
A0 |
Address 0
|
E1 |
D6 |
Data 6
|
E2 |
D4 |
Data 4
|
E3 |
MMIO# |
|
E4 |
BHEN |
|
E5 |
A19 |
Address 19
|
E6 |
A16 |
Address 16
|
E7 |
A12 |
Address 12
|
E8 |
DRQx# |
|
E9 |
IRQ2# |
Interrupt 2
|
E10 |
A5 |
Address 5
|
E11 |
A3 |
Address 3
|
E12 |
IRQ5# |
Interrupt 5
|
Floppy/EIDE (Bottom)
Pin |
Name |
Description
|
A1 |
FDSEL1 |
Floppy Select 1
|
A2 |
FDSEL0 |
Floppy Select 0
|
A3 |
FDME1 |
Floppy ?
|
A4 |
DIR |
Floppy Direction
|
A5 |
STEP |
Floppy Step
|
A6 |
WRDATA |
Floppy Write Data
|
A7 |
WE |
Floppy Write?
|
A8 |
TRK0 |
Floppy Track 0
|
A9 |
WP |
Floppy Write?
|
A10 |
RDDATA |
Floppy ?
|
A11 |
HDSEL |
Floppy HD Select
|
A12 |
DSKCHG |
Floppy DiskChange
|
B1 |
DRVDEN1 |
?
|
B2 |
DRVDEN0 |
?
|
B3 |
IDECS3P# |
IDE ?
|
B4 |
IDEA2 |
IDE ?
|
B5 |
IDEIRQS |
IDE ?
|
B6 |
IDEPUS |
IDE ?
|
B7 |
IDEDRQP |
IDE ?
|
B8 |
IDED14 |
IDE Data 14
|
B9 |
IDED8 |
IDE Data 8
|
B10 |
IDED6 |
IDE Data 6
|
B11 |
IDED11 |
IDE Data 11
|
B12 |
IDED3 |
IDE Data 3
|
C1 |
FDME0 |
Floppy Me?
|
C2 |
INDX |
Floppy Index
|
C3 |
IDECS3S# |
IDE ?
|
C4 |
IDEA0 |
IDE ?
|
C5 |
IDEDAKS# |
IDE ?
|
C6 |
IDEIOR# |
IDE ?
|
C7 |
IDEDRQS |
IDE ?
|
C8 |
IDED1 |
IDE Data 1
|
C9 |
#IDERST |
IDE ?
|
C10 |
IDED10 |
IDE Data 10
|
C11 |
IDED4 |
IDE Data 4
|
C12 |
IDED2 |
IDE Data 2
|
D1 |
IDELEDS# |
IDE LED ?
|
D2 |
IDELEDP# |
IDE LED ?
|
D3 |
IDECS1S# |
IDE ?
|
D4 |
IDEIRQP |
IDE ?
|
D5 |
IDEPUP |
IDE Pull Up ?
|
D6 |
IDEIOW# |
IDE ?
|
D7 |
IDED15 |
IDE Data 15
|
D8 |
IDED13 |
IDE Data 13
|
D9 |
IDED7 |
IDE Data 7
|
D10 |
GND |
Ground
|
D11 |
GND |
Ground
|
D12 |
GND |
Ground
|
E1 |
GND |
Ground
|
E2 |
GND |
Ground
|
E3 |
IDECS1P# |
IDE ?
|
E4 |
IDEA1 |
IDE ?
|
E5 |
IDEDAKP# |
IDE ?
|
E6 |
IDEIORDY |
IDE ?
|
E7 |
IDED0 |
IDE Data 0
|
E8 |
IDED12 |
IDE Data 12
|
E9 |
IDED9 |
IDE Data 9
|
E10 |
IDED5 |
IDE Data 5
|
E11 |
GND |
Ground
|
E12 |
GND |
Ground
|
SCSI (Bottom)
Pin |
Name |
Description
|
A1 |
TERM |
|
A2 |
GND |
Ground
|
A3 |
I/O# |
|
A4 |
REQ# |
|
A5 |
ATN# |
|
A6 |
D8 |
Data 8
|
A7 |
D9 |
Data 9
|
A8 |
D10 |
Data 10
|
A9 |
D2 |
Data 2
|
A10 |
D4 |
Data 4
|
A11 |
DP0 |
|
A12 |
GND |
Ground
|
B1 |
TERM |
|
B2 |
GND |
Ground
|
B3 |
GND |
Ground
|
B4 |
GND |
Ground
|
B5 |
GND |
Ground
|
B6 |
GND |
Ground
|
B7 |
GND |
Ground
|
B8 |
GND |
Ground
|
B9 |
GND |
Ground
|
B10 |
GND |
Ground
|
B11 |
GND |
Ground
|
B12 |
GND |
Ground
|
C1 |
TERM |
|
C2 |
GND |
Ground
|
C3 |
C/D# |
|
C4 |
MSG# |
|
C5 |
ACK# |
|
C6 |
D12 |
Data 12
|
C7 |
DP1 |
Data P1
|
C8 |
D13 |
Data 13
|
C9 |
D1 |
Data 1
|
C10 |
D5 |
Data 5
|
C11 |
D7 |
Data 7
|
C12 |
GND |
Ground
|
D1 |
TERM |
|
D2 |
GND |
Ground
|
D3 |
GND |
Ground
|
D4 |
GND |
Ground
|
D5 |
GND |
Ground
|
D6 |
GND |
Ground
|
D7 |
GND |
Ground
|
D8 |
GND |
Ground
|
D9 |
GND |
Ground
|
D10 |
GND |
Ground
|
D11 |
GND |
Ground
|
D12 |
GND |
Ground
|
E1 |
TERM |
|
E2 |
GND |
Ground
|
E3 |
SEL# |
|
E4 |
RST# |
|
E5 |
BSY# |
|
E6 |
D14 |
Data 14
|
E7 |
D15 |
Data 15
|
E8 |
D11 |
Data 11
|
E9 |
D0 |
Data 0
|
E10 |
D3 |
Data 3
|
E11 |
D6 |
Data 6
|
E12 |
GND |
Ground
|
Contributions
Sources